Agilent G6460C Mass Spec
Out of stock
Advanced Triple Quad LC/MS System
The Agilent 6460 is a triple quadrupole LC/MS system and features:
- Excellent sensitivity suitable for a wide range of proteomics applications
- No collision cell cross-talk with 1 ms dwell time
- Multi-analyte studies enabled with fast polarity switching
- Improved MRM efficiency with Dynamic Multiple Reaction Monitoring (dMRM)
- Simultaneous quantitation and confirmation with Triggered Multiple Reaction Monitoring (tMRM)
System Features
- Single point of control data system method capability with full control of Agilent 1200 Series HPLC systems and 6460C Triple Quadrupole LC/MS System
- Time programming
- Polarity change in time segment
- Scan and SIM or MRM (plus other modes of data collection)
- Dynamic and triggered MRM aligns MRMs with compound retention time
- Solvent divert through calibrant delivery system valve
- Wide range of ionization sources
- Electrospray (ESI)
- Nanospray with HPLC-Chip Cube MS interface
- APCI source (Atmospheric Pressure Chemical Ionization)
- Multimode source (simultaneous ESI and APCI)
- APPI source (Atmospheric Pressure Photo Ionization)
- Autotune - Automated optimization of ion optics and mass axis calibration in positive and
- negative ion modes using a proprietary tune solution
- Solvent declustering - Countercurrent gas
- Detector - High-energy conversion dynode and high-gain electron multiplier horn
- Vacuum system - Two turbomolecular pumps with one mechanical pump
Tune Report included.
MRM sensitivity S/N ESI pos: >30,000:1
MRM sensitivity S/N ESI neg: >10,000:1
MRM sensitivity IDL ESI pos: <12.5 fg
MRM sensitivity IDL ESI neg: <12.5 fg
Mass range: m/z 5-3,000
Polarity switching: 30 ms
Mass resolution FWHM autotune: 0.7 Da
Mass resolution FWHM manual: 0.5 Da
Mass accuracy: 0.1 Da from 5 – 1,000 m/z, 0.01% from 1,000 – 2,000 m/z, 0.02% from 2,000 – 3,000 m/z
Mass stability: <0.1 Da in 24 h
Dynamic range: >6.0 x 10e6
Scan modes: MS scan, MS/MS product ion scan, MRM, MS/MS neutral loss/gain scan and precursor ion scan, SIM
Max scan rate: 12,500 Da/s
Min MRM dwell time: 1 ms
MRM transitions: 450 / time segment, >40,000 ion transaction/method
Triggered MRM transitions: Up to 10
Collision cell ion clearance: <1 ms
We offer the following Service and Support Options:
- Installation
- Onsite or Remote Training
- Service and Preventative Maintenance contracts
- Application development
- Redeployment (relocate, sell, swap, dispose).
You can request information and a quote on the checkout screen or contact us here.